Dama outdoor
Installation manual
Last updating 04 of July 2024
INTRO
DAMA OUTDOOR is a wireless outdoor siren with power up to 112 dB at 1 meter, the flashing light is red high intensity that ensures a vision from afar. It installs and configures quickly thanks to easy-fix support and ensures a 5-year life with pre-installed batteries. The aesthetic line is pleasant thanks to a careful design study.
It is made of weather and UV resistant ABS. Thanks to the particular design of the gaskets guarantees a maximum water tightness and is in compliance with IP55.
OPERATION
DAMA OUTDOOR works within the D’AVINCI system with a range of up to 1500 meters (in free space) by connecting, via radio, directly to the Lisa control panel or via Automa repeater. The communication is bidirectional (transmission/reception) with the indication of confirmation of receipt and command. In the case of obstacles such as walls, objects, etc. the range is reduced. It uses a high-efficiency piezoelectric transducer that can deter any attackers. It also has tamper anti-tampering able to instantly signal the removal from the wall and the opening of the body.
The communication protocol, like the connections between all the components of the system, is the GENIO, encrypted and protected from interception.
Configuration takes place via D’AVINCI app downloadable for free from IOS and Android.
The Siren operates on two frequencies in the 868 MHz band, automatically and dynamically positioned on the one that is free or less interfered.
DEVICE CONFIGURATION IN THE D’AVINCI SYSTEM
Warning. Before adding the device:
- Install the D’AVINCI app, available for iOS/Android, on your smartphone.
- Create an account. Add a D’AVINCI Control Panel, save the necessary settings and create at least one Room
- Make sure the Control Panel is on and has internet access via Ethernet cable.
- Make sure that the Control Panel is off and not running updates by checking its status via the mobile application.
To add a device to the control panel, in the D’AVINCI app 1
- Select the Tab Device 2
- Click on Add Device
- Name the device
- Insert the serial number of the device shown on the label or click on icon to scan the code via the app.
- Select the associated Room for the device.
-
Click Add – a countdown will start.
-
Remove the tab from the batteries, so as to Power the device (see installation phase of the device).
The siren LEDs will emit flashes when it is switched on.When paired with the control panel, the siren will appear in the list of devices in the AVINCI App.
The connection request to the Control Panel is transmitted for a short period of time as soon as the device is switched on.
If the connection to the AVINCI control panel fails, turn off the detector for 5 seconds and repeat the procedure.
1 Installer privileges are required.
2 To start the configuration procedure, the device must be within the radio communication zone of the associated Control Panel.
Installation of the Siren
Make sure that you have selected the ideal installation location according to the guidelines in this manual.
The place of installation of the siren affects the connection with the control panel and any obstacles between the devices can block the transmission of the radio signal. Such obstacles can be walls, floors or large objects within a room. Be sure to install the siren on a flat surface, in a position not easily accessible in such a way as to minimize the risk of tampering.
If the signal level is low, stable operation of the safety system is not guaranteed. Please take any measures to improve the signal quality!
First, try to move the device
If this is not enough and the device still has a low or unstable signal strength, use a radio signal repeater.
To install the device:
Fix the support to the wall through the supplied screws.
Remove the tabs from the batteries.
Fix the Siren on the support with the special locking screw.
– Close to metal objects or mirrors which could attenuate or block the radio signal
– Next to other radio devices (gsm/wireless router/etc.) to avoid mutual interference
– In environments where the temperature or humidity values may exceed the limits specified in the characteristics
OPERATING SETTINGS
The detector settings can be changed in the D’AVINCI app (Installer privileges are required):
- Go to device tab
- Select the device from the list.
- Go to settings by clicking on the icon (gear)
DEVICE NAME
Siren name , display in the device list and as notification text.
It can hold up to 24 characters
ROOM
Selecting the virtual room to which the device is assigned the environment name appears in notifications.
Note: Changing this parameter requires Administrator privileges
SIREN VOLUME
Allows you to adjust the acoustic intensity of the device.
– Disabled
– Low
– Normal
– High
REPORTING TIME
Sets the duration of the device’s signal.
[ 5 – 180] seconds
SOUND TONE
Sets the sound tone of the siren.
[ 1 – 8] seconds
TAMPERING ALARM
Allows you to enable/disable the device acoustic warning in case of tampering
ALERT STATUS ARMED
Enables/disables the visual indication of the device when it is armed.
– Never: visual signalling is not enabled
– Inserted: visual signalling is enabled to implant inserted.
ACOUSTIC SETTINGS
Enables/disables the acoustic indication of the device.
–Switched on/off: If enabled, the siren warns of on and off
with a light indication and a short beep.
-Switched on/off Stay : if enabled, the siren warns of the insertion and the
Stay mode deactivation with a light indication and a short acoustic signal.
-Input delay: If enabled, the siren will sound, with a short beep, a
late entry
-Output delay: if enabled, the siren beeps for a short delay
on exit.
-Stay mode input delay: if enabled, the siren signals with a short signal
acoustic, a delay at the entrance in Stay mode
-Stay mode output delay: if enabled, the siren signals with a short signal
acoustic, an outgoing delay in Stay mode
REPEATER
Enables the connection of the device to the system through a repeater ( Automa).
– Repeater number: indicates the number of the repeater to which the device is associated.
VERIFICATION OF RADIO CONNECTION
Enables alarm warning in case of failure to communicate with the
central. If disabled, the report of failure to connect to the central will be
exclusively archived.
Ping interval: time interval, in seconds, between a transmission of
survival and the next in the absence of activation.
– [ 12 :600 ] seconds
Ping number: number of connection attempts before failure report
radio communication
– [ 1 : 15 ]
RADIO SIGNAL INTENSITY TEST
With this function, the device after pressing the START button processes a test where it will indicate the signal level , flashing the led n times depending on the result obtained.(1-4)
TEST VOLUME
With this function, the device after pressing the START button will perform an acoustic test.
EXCLUDE DEVICE
By selecting this button, the device is completely excluded from the operation of the
system, not signaling alarms or events.
No: The device works normally and transmits all events/alarms
All: The device does not execute the sent commands. The system ignores the
device and its notifications.
Lid Only: The system ignores notifications about activating the (tamper) button
tampering with the device.
REMOVE DEVICE
Dissociate the detector from the Control Panel, removing it from the app and deleting the device settings.
INTENSITY GENIO SIGNAL
To display the signal strength select the card Devices and the signal level field GENIO
0 = No radio signal, no connection to control panel.
• = Poor radio signal, unstable connection with the Control Panel , operation of the detector not guaranteed.
• • = Low radio signal, low signal strength.
• • • = Good radio signal, good signal strength.
• • • • = Excellent radio signal, optimal signal strength.
Check the radio signal strength before the final installation of the device. In case of low or unstable signal it is recommended to use the Automa repeater.
DEVICE status
To view the status:
- Access the D’AVINCI application
- Select the Control Panel on which the detector is associated
- Go to Devices tab
- Select the detector
Icon | Description | Note |
Connection status | - Online: connection established with the control panel
- Offline: connection error with the control panel |
|
Genio signal level | - 0
- 1 - 2 - 3 - 4 | |
Battery level |
- 25 %
- 50 % - 75 % - 100 % | |
Tamper status | - Alarm
- Regular | |
External power supply status | - Disconetted
- Connected | |
Siren Volume | - Disabled
-Low - Normal - High | |
Reporting time | 5 sec. / 3 Min. | |
Beep tone | 1 / 8 | |
Signaling status inserted | - Never
- Inserted | |
Device exclusion status | - No
- Total - Lid only |
|
Repetear use | - NO
- YES (1-5) |
REPLACING THE BATTERIES
If the battery of the detector is low, the user receives a notification via app
Unscrew the mounting screw from the wall bracket
Release the Siren from the stirrup.
Remove the empty batteries and replace them with new ones.
Reassemble the Siren on its bracket and tighten the screw to lock it.
WARNINGS AND MALFUNCTIONS
– the siren is removed from the installation location or the siren cover is opened
(tamper anti-tampering active)
– No radio communication between power station and siren
– The siren battery is low
Event | Indication | |
Start device | All LEDs flash for 3 seconds | |
Alarm | It beeps and the frame flashes red | |
System armed | Flashing yellow LED with one break of 10 seconds | |
Setting | The led frame flashes once and emits a short beep | |
Unsetting | The led frame flashes 2 times and emits a short beep | |
Flat battery inserted | Yellow LED flashes for 3 seconds |
technical specifications
Type of device | Outdoor siren (Piezoelectric Transducer) |
Acoustic signal | 3 min, configurable via app |
Anti sabotage protection | - antijammer
- tamper anti opening and anti tear |
LED Indication | - System signal inserted with yellow LED
- Alarm signal 4 red LED with high brightness, with signaling mode configurable via app |
Additional input | Yes for 12 volts power supply |
Radio communication protocol | Genio |
Operating frequencies | 868.20 Mhz 868.95 Mhz |
RF signal power | 13 dB |
Modulation | GFSK |
Radio signal range | Up to 1500 m |
Power supply | 4 CR123A – 12V batteries |
Battery life | 5 years |
Installation | Outdoor |
Protection class | IP55 |
Operating temperatures | from -25°С to +55°С |
Maximum allowable humidity | Up to 95% |
Dimensions | 195x198x45 mm |
Weight | 604 grams |