Astro
Installation manual
Last updating August 27 2024
INTRO
ASTRO is a volumetric detector with wireless curtain effect, from indoor to dual technology ( IR + MW). It works for up to 5 years with the battery pre-installed and is equipped with an infrared capable of detecting the presence of intruders within a radius of 12 meters for 15 years, with an installation height of 2.1 meters. Easy-fix mounting bracket for easy installation.
Ideal for perimeter protection of corridors, doors, windows and windows.
OPERATION
ASTRO works within the D’AVINCI system with a range of up to 1500 meters (in free space) by connecting, via radio, directly to the Lisa Control Unit or via Automa repeater. The communication is bidirectional (transmission/reception) with the indication of confirmation of receipt and command. In the case of obstacles such as walls, objects, etc. the range is reduced.
The communication protocol, like the connections between all the components of the system, is the GENIO, encrypted and protected from interception.
The sensor configuration is via D’AVINCI app downloadable free of charge from IOS and Android.
Antimask active on IR for lens contact blinding.
Configuration of the IR sensitivity on two levels, warning LEDs for alarm.
The detector operates on two frequencies in the 868 MHz band, automatically and dynamically positioned on the one that is free or less interfered.
DEVICE CONFIGURATION IN THE D’AVINCI SYSTEM
Warning. Before adding the device:
- Install the D’AVINCI app, available for iOS/Android, on your smartphone.
- Create an account. Add a D’AVINCI Control Panel, save the necessary settings and create at least one Room
- Make sure the Control Panel is on and has internet access via Ethernet cable.
- Make sure the Control Panel is off and not running updates by checking its status via the mobile application.
How to connect the detector to the Control Panel:1
- Select the tab Device 2
- Click on Add Device
- Name the Device
- Insert the device serial number on the label or click on the icon
to acquire the code via app
- Select the Room associated for the device
- Click on Add – a countdown will start
- Turn on the device by pressing the ON/OFF button on the back (see installation phase of the device).
The detector light will start flashing red.
When paired with the control panel, the detector will appear in the list of devices in the D’AVINCI App.
Then it will be necessary to close the tamper, placing it on its bracket , this to allow you to carry out the calibration phase, with the flashing yellow LED for about a minute. When the warning lamp is switched off, the device is ready to detect movements and transmit them to the control panel.
The connection request to the Control Panel is transmitted for a short period of time as soon as the device is switched on.
If the connection to the D’AVINCI control panel fails, turn off the detector for 5 seconds and repeat the procedure.
1 Installer privileges are required.
2 To start the configuration procedure, the device must be within the radio communication zone of the associated Control Panel.
DETECTOR INSTALLATION
Make sure you have selected the ideal installation location according to the guidelines in this manual.
The location of the sensor affects the connection to the Control Panel and any obstacles between the devices may block the transmission of the radio signal. Such obstacles can be walls, floors or large objects within a room.
To install the detector

Fix the bracket to the wall using the screws supplied.


Turn on the device via the button on the back.

Fix the detector on its support.

- In unprotected areas or premises (outdoors).
- Near metal objects or mirrors that may attenuate or block the radio signal.
- Next to other radio devices (gsm/wireless router/etc.) to avoid mutual interference
- In environments where temperature or humidity values may exceed the limits specified in the Technical Specifications.
OPERATING SETTINGS
The detector settings can be changed in the D’AVINCI app (Installer privileges are required):
- Go to device tab
- Select the device from the list.
- Go to settings by clicking on the icon (gear)
DEVICE NAME
Detector name, displayed in the device list and as notification text. It can contain up to 24 characters.
ROOM
Selecting the virtual room to which the device is assigned the environment name appears in notifications.
Note: Changing this parameter requires Administrator privileges
METHOD OF ALARM
It shows how the detector reacts to alarms.
– Instantaneous: the detector, when the system is in place, immediately signals the alarm.
– Delayed: the detector, with the system inserted, signals the alarm after a time counter (see input/ output delay).
Input delay: 5 to 120 seconds.
Entry delay is the time that the user has to disconnect the system after entering the protected area.
Output delay: 5 to 120 seconds.
Exit delay is the time that the user has to leave the protected area after insertion.
– Continued: The detector adds input/output delays of devices that detected an alarm before it. When activated individually, it immediately triggers the alarm.
STAY MODE ARMED
Pairing the detector to night mode. This type of insertion allows, for example, to insert the perimeter area and allows people to move freely in other areas.
- Input delay in stay mode: 5 to 120 seconds.
Entry delay is the time that the user has to disconnect the system after entering the protected area. - Output delay in stay mode: 5 to 120 seconds.
Exit delay is the time that the user has to leave the protected area after insertion.
ALWAYS ACTIVE
If this option is enabled, the detector is always armed, detects the alarm condition and sends the signal to the Control Panel.
SENSITIVITY
Motion detector sensitivity level (infrared)
-Normal
-Low
MW REGULATION
Adjusts the microwave level [ 25%, 50%, 75% 100%]
TIME OF INHIBITION
time interval when the sensor does not detect the alarm condition
– None
– 30 seconds
-1 min
-2 min
ENABLE MASK
Enables/disables the anti-masking function.
EXCLUSION MW
Enables/disables the microwave sensor.
– Never
– Alarm off : green active functionality (disable emissions)
– always
SOUND ON THE ALARM
It allows you to activate the siren in case of alarm signal, if the system is armed
SIREN ON WITH LID OPEN
It allows you to activate the siren in case the detector is in the tamper state (tamper anti-opening or anti-tampering open).
ACTIVE SIREN IN MASK
Activates the siren in case of masking signal.
NUMBER OF ALARMS FOR SELF-EXCLUSION
Allows you to enter the number of alarms for the detector, during the same insertion, which cause the automatic exclusion of the detector. The detector will be automatically included the next time the system is inserted.
– Disabled
– 3 , 6, 9, 12 , 15.
WARNING LAMP
Enables the light indication for the alarm signal.
– only test operation
– always
REPEATER
Enables the connection of to the system through a repeater, eg Automa.
– Repeater number: indicates the number to which the detector is associated.
VERIFICATION OF RADIO CONNECTION
Allows you to enable the alarm in case of failure to communicate with the Central. If disabled, the report of failure to connect to the Central will be stored exclusively.
PING INTERVAL
Time interval, in seconds, between one survival transmission and the next in the absence of activation.
[ 12 : 600 ] seconds
NUMBER OF PING EXPECTED
Number of connection attempts before radio failure report
[ 1: 15 ]
RADIO SIGNAL INTENSITY TEST
With this function, the device after pressing the START button processes a test where it will indicate the signal level , flashing n times depending on the result obtained.(1-4)
DETECTION TEST
With this function, the device after pressing the START button will enter the test mode, keeping the LED always on and each valid movement will turn off to indicate an alarm detection.
EXCLUDE
No: the device works normally and transmits all events/alarms.
Total: The device does not execute the sent commands. The system ignores the
device and its notifications.
Tamper Only: The system ignores notifications regarding activation of the device’s tamper button (tamper).
REMOVE DEVICE
Dissociate the detector from the Control Panel, removing it from the app and deleting the device settings.
INTENSITY GENIO SIGNAL
To display the signal strength select the card Devices and the signal level field GENIO
0 = No radio signal, no connection to control panel.
• = Poor radio signal, unstable connection with the Control Panel , operation of the detector not guaranteed.
• • = Low radio signal, low signal strength.
• • • = Good radio signal, good signal strength.
• • • • = Excellent radio signal, optimal signal strength.
Check the radio signal strength before the final installation of the device. In case of low or unstable signal it is recommended to use the Automa repeater.
DEVICE status
The status shows information and parameters of operation of the device.
To view the status:
- Access the D’AVINCI application
- Select the Control Panel on which the detector is associated
- Go to Devices tab
- Select the detector
Icon | Description | Note |
![]() |
Connection status | - Online: connection established with the control panel
- Offline: connection error with the control panel |
![]() |
Genio signal level | - 0
- 1 - 2 - 3 - 4 |
![]() |
Battery level |
- 25 %
- 50 % - 75 % - 100 % |
![]() |
Tamper status | - Regular
– Alarm |
![]() |
Anti-masking status | - Regular: normal operation
- Mask: masking device, anomaly |
![]() |
Primary input status | – Regular
- Alarm |
![]() |
Sensitivity | – Normal
– Low |
![]() |
MW regulation | - 25%%
- 50% - 75% - 100% |
![]() |
Device exclusion status | - No
- Total - Lid only |
![]() |
Always active | - No
- Yes |
![]() |
Alarm Mode | - Instant
- Delayed - Continued |
![]() |
Arming in stay mode | - No
- Yes |
![]() |
Repeater use | - No
- Yes (1-5) |
rEPLACING THE BATTERIES
To clean the detector, avoid the use of substances containing alcohol, acetone, gasoline or other active solvents.
The battery life of the detector depends on the quality of the battery, the frequency of activation of the detector and the ping interval between detector and Central.
If the battery of the detector is low, the user receives a notification via D’AVINCI app.

Slide the sensor from its bracket.

Unscrew the screw on the back.


Take out the battery and replace it with a new one, close the sensor and place it back on your anchor bracket.
WARNING AND MALFUNCTIONS
The function of indicating warnings and malfunctions is enabled in the device settings, selecting the field Warning light.
Indication | Event |
Yellow LED flashes on* *visible only in detection test mode |
IR stage activation |
Green LED flashes on* *visible only in detection test mode |
MW stage activation |
Red LED flashes on | Alarm signal |
Yellow LED short alternating flashing every sec. |
Antimask initialization and calibration phase |
A malfunction appears if:
- Detector is removed from installation location or detector housing is open (tamper anti-tampering active)
- There is no radio communication between the control panel and the detector
- Detector battery is low
TECHNICAL SPECIFICATIONS
Type of sensor | Radio curtain detector (IR + MW) indoor |
Detector capacity | 2000 detections |
Detector range | Up to 12 meters (15°) |
Anti-sabotage protection | - antijammer
- anti-opening tamper |
Revelation Logic | And / Or |
Sensitivity | Programmable from the app |
Type Microwave | 24 GHz |
Antimask | Active on IR section |
Radio communication protocol | Genio |
Operating frequencies | 868.20 MHz 868.95 MHz |
RF signal power | 13 dBm |
Modulation | GFSK |
Radio signal range | Up to 1500 m |
Power supply | 1 CR123A – 3V battery |
Battery life | 5 years |
Installation | Indoor |
Installation height | 2.1 meters |
Protection class | IP40 |
Operating temperatures | from -15°С to +55С |
Maximum allowable humidity | Up to 95% |
Dimensions | 148x41x48 mm |
Weight | 109 grams |
CERTIFICATION