Atlantico

Installation manual

Last updating August 27 2024

INTRO

Atlantico is a dual technology outdoor wireless volumetric detector ( 2 IR + MW). It works for up to 5 years with batteries preinstalled and is equipped with a double infrared capable of detecting the presence of intruders within a radius of 12 meters to 107 years (90 years with microwave enabled), with an installation height of 1.2 meters, immune pet function, easy-fix mounting bracket for easy installation. Ideal for protecting outdoor areas such as gardens , terraces , garages, etc

OPERATION

ATLANTICO works within the D’AVINCI system with a range of up to 1500 meters (in free space) by connecting, via radio, directly to the Lisa Control panel or via Automa repeater. The communication is bidirectional (transmission/reception) with the indication of confirmation of receipt and command. In the case of obstacles such as walls, objects, etc. the range is reduced.

The communication protocol, like the connections between all the components of the system, is the GENIO, encrypted and protected from interception.
The sensor configuration is via D’AVINCI app downloadable free of charge from IOS and Android.

Antimask active on IR for lens contact blinding.
Configuration of the IR sensitivity on three levels, warning LEDs for alarm.
The detector operates on two frequencies in the 868 MHz band, automatically and dynamically positioned on the one that is free or less interfered.

DEVICE CONFIGURATION IN THE D’AVINCI SYSTEM

Before adding a device:

    1. Install the app D’AVINCI, available for iOS / Android, on your smartphone.
    2. Create a account . Add a D’AVINCI alarm panel, save the necessary settings and create at least a room.
    3. Make sure the Control Panel is turned on and has Internet access via Ethernet.
    4. Make sure the control panel is switched off and not running updates by checking its status via the mobile application.

How to connect the detector to the Control Panel:1

  1. Select the tab Device 2 
  2. Click on Add Device 
  3. Name the Device
  4. Insert the device serial number on the label or click on the icon to acquire the code via app
  5. Select the Room associated for the device
  6. Click Add-a countdown will start.
  7. Turn on the device by pressing the ON/OFF button on the back (see installation phase of the device).
    The detector top pir light will start flashing red. When paired with the control panel, the detector will appear in the list of devices in the D’AVINCI app.Then it will be necessary to close the tamper, placing it on its bracket, this to allow you to carry out the calibration phase, with the yellow blinking LED of the upper pir and lower pir, for about a minute. After that, the lights will turn off and the device will be ready to detect movements and transmit them to the control panel.The connection request to the Control Panel is transmitted for a short period of time as soon as the device is switched on. If the connection to the D’avinci control panel fails, switch off the detector for 5 seconds and repeat the procedure.

1 Installer privileges are required.

2 To start the configuration procedure, the device must be within the radio communication zone of the associated Control Panel.

Detector installation

Make sure that you have selected the ideal installation location according to the guidelines in this manual.
The installation location of the sensor affects the connection with the control panel and any obstacles between the devices can block the transmission of the radio signal. Such obstacles can be walls, floors or large objects.

To install the device:

Fix the bracket to the wall using the screws supplied.

Turn on the device via the button provided.

Fix the detector on the holder.

Tighten the locking screw on the support.

Place the cap on top of the sensor.

Do not install the detector:
– In areas with a strong presence of tall plants that can disturb the detector with the wind.
– Next to other radio devices (gsm/wireless router/etc.) to avoid mutual interference
– In environments where the temperature or humidity values may exceed the limits specified in the technical specifications

OPERATING SETTINGS

The detector settings can be changed in the D’AVINCI app (Installer privileges are required):

  1. Go to device tab
  2. Select the device from the list.
  3. Go to settings by clicking on the icon

DEVICE NAME
Detector name, displayed in the device list and as notification text. It can contain up to 24 characters.

ROOM
Selecting the virtual room to which the device is assigned the environment name appears in notifications.
Note: Changing this parameter requires Administrator privileges

METHOD OF ALARM
It shows how the detector reacts to alarms.

Instantaneous: the detector, when the system is in place, immediately signals the alarm.

Delayed: the detector, with the system inserted, signals the alarm after a time counter (see input/ output delay).

Input delay: 5 to 120 seconds.
Entry delay is the time that the user has to disconnect the system after entering the protected area.
Output delay: 5 to 120 seconds.
Exit delay is the time that the user has to leave the protected area after insertion.

– ContinuedThe detector adds input/output delays of devices that detected an alarm before it. When activated individually, it immediately triggers the alarm

STAY MODE ARMED
Pairing the detector to night mode. This type of insertion allows, for example, to insert the perimeter area and allows people to move freely in other areas.

  • Input delay in stay mode: 5 to 120 seconds.
    Entry delay is the time that the user has to disconnect the system after entering the protected area.
  • Output delay in stay mode: 5 to 120 seconds.
    Exit delay is the time that the user has to leave the protected area after insertion.

ALWAYS ACTIVE

If this option is enabled, the detector is always armed, detects the alarm condition and sends the signal to the Control Panel.

TYPE OF DETECTION

PET function: The detector allows small pets to move freely when the system is inserted.

With Creep: The detector, with the system inserted, is sensitive to any attempts at creep.

SENSITIVITY
Motion detector sensitivity level (infrared)
– High
-Normal
-Low

MW REGULATION
Adjusts the microwave level [ 25%, 50%, 75% 100%]

TIME OF INHIBITION
time interval when the sensor does not detect the alarm condition
– None
– 30 seconds
-1 min
-2 min

ENABLE MASK
Enables/disables the anti-masking function

EXCLUSION MW
Enables/disables the microwave sensor.
– Never
– Alarm off : green active functionality (disables emissions)
– always

SOUND ON THE ALARM
It allows you to activate the siren in case of alarm signal, if the system is armed

SIREN ON WITH LID OPEN
It allows you to activate the siren in case the detector is in the tamper state (tamper anti-opening or anti-tampering open).

ACTIVE SIREN IN MASK
Activates the siren in case of masking signal.

NUMBER OF ALARMS FOR SELF-EXCLUSION
Allows you to enter the number of alarms for the detector, during the same insertion, which cause the automatic exclusion of the detector. The detector will be automatically included the next time the system is inserted.
– Disabled
– 3 , 6, 9, 12 , 15.

WARNING LAMP
Enables the light indication for the alarm signal.
– only test operation
– always

REPEATER
Enables the connection of to the system through a repeater, eg Automa.

– Repeater number: indicates the number to which the detector is associated.

VERIFICATION OF RADIO CONNECTION
Allows you to enable the alarm in case of failure to communicate with the Central. If disabled, the report of failure to connect to the Central will be stored exclusively.

PING INTERVAL
Time interval, in seconds, between one survival transmission and the next in the absence of activation.
[ 12: 600 ] seconds

NUMBER OF PING EXPECTED
Number of connection attempts before radio failure report
[ 1 :15 ]

RADIO SIGNAL INTENSITY TEST
With this function, the device after pressing the START button processes a test where it will indicate the signal level , flashing n times depending on the result obtained.(1-4)

DETECTION TEST
With this function, the device after pressing the START button will enter the test mode, keeping the LED always on and each valid movement will turn off to indicate an alarm detection.

EXCLUDE DEVICE
No: the device works normally and transmits all events/alarms.
Total: The device does not execute the sent commands. The system ignores the
device and its notifications.
Tamper Only: The system ignores notifications regarding activation of the device’s tamper button (tamper).

REMOVE DEVICE
Dissociate the detector from the Control Panel, removing it from the app and deleting the device settings.

INTENSITY GENIO SIGNAL

The level of the radio signal GENIO is determined by the number of packets sent by the detector and the actual number of packets received by the associated control panel.

To display the signal strength select the card Devices and the signal level field GENIO

0 = No radio signal, no connection to control panel.
= Poor radio signal, unstable connection with the Control Panel , operation of the detector not guaranteed.
• • = Low radio signal, low signal strength.
• • • = Good radio signal, good signal strength.
• • • • =  Excellent radio signal, optimal signal strength.

Check the radio signal strength before the final installation of the device. In case of low or unstable signal it is recommended to use the Automa repeater.

DEVICE status

The status shows information and parameters of operation of the device.
To view the status:

  1. Access the D’AVINCI application
  2. Select the Control Panel on which the detector is associated
  3. Go to Devices tab
  4. Select the detector
Icon Description Note
Connection status - Online: connection established with the control panel
- Offline: connection error with the control panel
Genio signal level - 0
- 1
- 2
- 3
- 4
Battery level - 25 %
- 50 %
- 75 %
- 100 %
Tampering status - Alarm
- Regular
Antimask status - Normal : normal operation
- Mask : masking device
Input primary status - Regular
- Alarm
PET function - Enabled
- Disabled
Sensitivity - High
- Normal
- Low
MW regulation - 25%
- 50%
- 75%
- 100%
Exclusion status device - No
- Total
- Only lid
Always active - No
- Yes
Alarm mode status - Instant
- Delayed
- Continued
Arming in stay mode - No
- Yes
Repeater use - No
- Yes (1-5)

Replacing the batteries

Keep the detector housing clean by immediately removing dust, cobwebs and other impurities. Use a soft, dry towel for equipment maintenance.
To clean the detector, avoid the use of substances containing alcohol, acetone, gasoline or other active solvents.

The battery life of the detector depends on the quality of the battery, the frequency of activation of the detector and the ping interval between detector and Central.

If the battery of the detector is low, the user receives a notification via D’AVINCI app.

WARNING AND MALFUNCTIONS

The function of indicating warnings and malfunctions is enabled in the device settings, selecting the field Warning light.

Indication Event
Yellow LED bottom on*
*visible only in detection test mode
IR stage activation
Yellow LED top on*
*visible only in detection test mode
IR stage activation
Green LED on*
*visible only in detection test mode
MW stage activation
Red LED on Alarm signal
YELLOW LED PIR upper and lower
short alternating flashing every sec.
Antimask phase initialization and calibration
RED LED
short alternating flashing every sec.
Waiting for tamper closure

A malfunction appears if:

  • Detector is removed from installation location or detector housing is open (tamper anti-tampering active)
  • There is no radio communication between the control panel  and the detector
  • Detector battery is low

TECHINICAL SPECIFICATIONS

Sensor type Dual technology detector(2 IR + MW) outdoor
Detector capacity 2000 detections
Detector range - 90 ° per 12 metres
- 107° per 12 metres excluding MW
Anti-sabotage protection - antijammer
- anti-tamper (anti-tear)
- anti-opening tamper
Radio communication protocol Genio
Microwave type 24 GHz
Operating frequencies 868.20 Mhz
868.95 Mhz
RF signal power 13 dB
Modulation type GFSK
Radio signal range Up to 1500 m
Power supply 2 CR123A – 3V battery
Battery life 5 years
Installation Outdoor
Installation height 1.2 meters
Protection class IP54
Operating temperatures From -15°С to +55С
Maximum humidity Up to 95%
Dimensions 70x200x63 mm
Weight 95 g

CERTIFICATION

D'AVINCI Security Products Srl
Via Antonio Tolomeo Trivulzio, 1
20146 - Milano

info@davincisecurity.it

FOLLOW US

Copyright 2023 - 2024 – D’AVINCI Security Products Srl – C.F. e P.IVA 12908830966 – All right reserved. || privacy policy