Nibbio+

Installation manual

Last updating 03rd of July 2024

INTRO

Nibbio+  is an indoor wireless door and window opening detector with impact detector and inclinometer. The battery is preinstalled, has a life of up to 5 years, and is equipped with an internal REED contact and the relative magnet.It also has an auxiliary input (AUX input) that can be programmed to operate in impulse mode , with programmable digital or state pulse counter (for the connection of an additional NC magnetic contact). Easy-fix mounting bracket for easy installation.

OPERATION

Nibbio+ works within the D’AVINCI system with a range of up to 1500 meters (in free space) by connecting, via radio, directly to the Lisa control panel or via Automa repeater. The communication is bidirectional (transmission/reception) with the indication of confirmation of receipt and command. In the case of obstacles such as walls, objects, etc. the range is reduced.

The communication protocol, like the connections between all the components of the system, is the GENIO, encrypted and protected from interception.
The sensor configuration is via D’AVINCI app downloadable free of charge from IOS and Android.

The detector operates on two frequencies in the 868 MHz band, automatically and dynamically positioned on the one that is free or less interfered.

DEVICE CONFIGURATION IN THE D’AVINCI SYSTEM

Warning. Before adding a device:

    1. Install the app D’AVINCI, available for iOS / Android, on your smartphone.
    2. Create a account . Add a D’AVINCI control panel, save the necessary settings and create at least a room.
    3. Make sure the Control Panel is turned on and has Internet access via Ethernet.
    4. Make sure the control panel is switched off.

To add a device to the control panel, in the D’AVINCI app  1

  1. Select the Tab Device 2  
  2.  Click on Add Device 
  3.  Name the device
  4. Insert the serial number of the device shown on the label  or click on icon  to scan the code via the app.
  5. Select the associated Room for the device.
  6. Click on Add – a countdown will start
  7. Remove the tab from the battery, so as to Power the device (see installation phase of the device).                                                                                                                                                       

      The detector led will emit a flashing light when it is switched on.

      When paired with the control panel, the detector will appear in the list of devices in the D’AVINCI App 

      The connection request to the Control Panel is transmitted for a short period of time as soon as the device is switched on.

      If the connection to the D’AVINCI control panel fails, turn off the detector for 5 seconds and repeat the procedure.

      1 Installer privileges are required.

      2 To start the configuration procedure, the device must be within the radio communication zone of the associated Control Panel.

    DETECTOR INSTALLATION

    Make sure that you have selected the ideal installation location according to the guidelines in this manual.
    The installation location of the sensor affects the connection with the control panel and any obstacles between the devices can block the transmission of the radio signal. Such obstacles can be walls, floors or large objects within a room.
    Make sure you have aligned the detector in the right direction with the magnet before fixing it. On one side there is a small protrusion at the height of the led that indicates the presence of the inner reed where it will be flanked by the magnet.

    To install the detector:

    Fix the bracket to the wall using the screws supplied.

    Pull out the battery tab on the back of the detector.

    Fix the detector and magnet on its support.

    Do not install the detector:

    • In unprotected areas or premises (outdoors).
    • Near metal objects or mirrors that may attenuate or block the radio signal.
    • Next to other radio devices (gsm/wireless router/etc.) to avoid mutual interference
    • In environments where temperature or humidity values may exceed the limits specified in the Technical Specifications.

    OPERATING SETTINGS

    The detector settings can be changed in the D’AVINCI app (Installer privileges are required):

    1. Go to device tab
    2. Select the device from the list.
    3. Go to settings by clicking on the icon

    DEVICE NAME
    Detector name, displayed in the device list and as notification text. Can contain up to 24 characters.

    ROOM
    Selecting the virtual room to which the device is assigned the environment name appears in notifications.
    Note: Changing this parameter requires Administrator privileges

    METHOD OF ALARM
    It shows how the detector reacts to alarms.

    Instantaneous: the detector, when the system is in place, immediately signals the alarm.

    Delayed: the detector, with the system inserted, signals the alarm after a time counter (see input/ output delay).

    Input delay: 5 to 120 seconds.
    Entry delay is the time that the user has to disconnect the system after entering the protected area.
    Output delay: 5 to 120 seconds.
    Exit delay is the time that the user has to leave the protected area after insertion.

     Continued: The detector adds input/output delays of devices that detected an alarm before it. When activated individually, it immediately triggers the alarm

    STAY MODE ARMED
    Pairing the detector to night mode. This type of insertion allows, for example, to insert the perimeter area and allows people to move freely in other areas.

    • Input delay in stay mode: 5 to 120 seconds.
      Entry delay is the time that the user has to disconnect the system after entering the protected area.
    • Output delay in stay mode: 5 to 120 seconds.
      Exit delay is the time that the user has to leave the protected area after insertion.

    ALWAYS ACTIVE

    If this option is enabled, the detector is always armed, detects the alarm condition and sends the signal to the Control Panel.

    SENSITIVITY
    Motion detector sensitivity level (infrared)
    – High
    -Normal
    -Low

    TIME OF INHIBITION
    time interval when the sensor does not detect the alarm condition
    – None
    – 30 seconds
    -1 min
    -2 min

    ENABLE MASK
    Enables/disables the anti-masking sensor.

    SOUND ON THE ALARM
    It allows you to activate the siren in case of alarm signal, if the system is inserted.

    SIREN ON WITH LID OPEN
    It allows you to activate the siren in case the detector is in the tamper state (tamper anti-opening or anti-tampering open).

    ACTIVE SIREN IN DISGUISE
    Activates the siren in case of masking signal.

    NUMBER OF ALARMS FOR SELF-EXCLUSION
    Allows you to enter the number of alarms for the detector, during the same insertion, which cause the automatic exclusion of the detector. The detector will be automatically included the next time the system is inserted.
    – Disabled
    – 3 , 6, 9, 12 , 15.

    WARNING LAMP
    Enables the light indication for the alarm signal.
    – only test operation
    – always

    REPEATER
    Enables the connection of to the system through a repeater, eg Automa.

    – Repeater number: indicates the number to which the detector is associated.

    VERIFICATION OF RADIO CONNECTION
    Allows you to enable the alarm in case of failure to communicate with the Central. If disabled, the report of failure to connect to the Central will be stored exclusively.

    PING INTERVAL
    Time interval, in seconds, between one survival transmission and the next in the absence of activation.
    [ 12 600 ] seconds

    NUMBER OF PING EXPECTED
    Number of connection attempts before radio failure report
    [ 1 15 ]

    RADIO SIGNAL INTENSITY TEST
    With this function, the device after pressing the START button processes a test where it will indicate the signal level , flashing n times depending on the result obtained.(1-4)

    DETECTION TEST
    With this function, the device after pressing the START button will enter the test mode, keeping the LED always on and each valid movement will turn off to indicate an alarm detection.

    EXCLUDE  DEVICE
    No: the device works normally and transmits all events/alarms.
    Total: The device does not execute the sent commands. The system ignores the
    device and its notifications.
    Tamper Only: The system ignores notifications regarding activation of the device’s tamper button (tamper).

    REMOVE DEVICE
    Dissociate the detector from the Control Panel, removing it from the app and deleting the device settings.

    INTENSITY GENIO SIGNAL

    The level of the radio signal GENIO is determined by the number of packets sent by the detector and the actual number of packets received by the associated control panel.

    To display the signal strength select the card Devices and the signal level field GENIO

    0 = No radio signal, no connection to control panel.
    = Poor radio signal, unstable connection with the Control Panel , operation of the detector not guaranteed.
    • • = Low radio signal, low signal strength.
    • • • = Good radio signal, good signal strength.
    • • • • =  Excellent radio signal, optimal signal strength.

    Check the radio signal strength before the final installation of the device. In case of low or unstable signal it is recommended to use the Automa repeater.

    DEVICE STATUS

    The status shows information and parameters of operation of the device.
    To view the status:

    1. Access the D’AVINCI application
    2. Select the Control Panel on which the detector is associated
    3. Go to Devices tab
    4. Select the detector
    Icon Description Note
    Connection status - Online: connection established with the control panel
    - Offline: connection error with the control panel
    Genio signal level - 0
    - 1
    - 2
    - 3
    - 4
    Battery level - 25 %
    - 50 %
    - 75 %
    - 100 %
    Tamper Status - Regular
    - Alarm
    Primary input status - Regular
    - Alarm
    External input status - Regular
    - Alarm
    Impact sensor status - Regular
    - Alarm
    Inclinometer status - Regular
    - Alarm
    Device exclusion status - No
    - Entirely
    - Lid only
    Always active - No
    - Yes
    Alarm Mode - Instant
    - Delayed
    - Continued
    Arming in Stay Mode - No
    - Yes
    Repeater use - No
    - Yes (1-5)

    REPLACING THE BATTERIES

    Keep the detector housing clean by immediately removing dust, cobwebs and other impurities. Use a soft, dry towel for equipment maintenance.
    To clean the detector, avoid the use of substances containing alcohol, acetone, gasoline or other active solvents.

    The battery life of the detector depends on the quality of the battery, the frequency of activation of the detector and the ping interval between detector and Central.

    If the battery of the detector is low, the user receives a notification via D’AVINCI app.

    WARNING AND MALFUNCTIONS

    The function of indicating warnings and malfunctions is enabled in the device settings, selecting the field Warning light.

    Indication Event
    Red LED flashing System status alarm armed
    Red LED 3 flashes (for Survival) Missing radio link
    Red LED flashes 3 times when turned on Flat battery inserted

    A malfunction appears if:
    – the detector is removed from the installation location or the housing is open (tamper anti-tampering active).
    – There is no radio communication between the control panel and the detector
    – Detector battery is low

    TECHNICAL SPECIFICATIONS

    Sensor type Door/ window opening detector with inclinometer and impact
    Detector capacity 2000 detections
    Detector activation limit 2 cm
    Anti-sabotage protection - antijammer
    - anti-opening tamper
    Additional input Yes, for any NC wired detectors
    Radio communication protocol Genio
    Operating frequencies 868.20 Mhz
    868.95 Mhz
    RF signal power 13 dB
    Modulation GFSK
    Radio signal range Up to 1500 m
    Power supply 1 CR123A – 3V battery
    Battery life 5 years
    Installation Indoor
    Protection class IP40
    Operating temperatures from -10°С to +40°С
    Maximum allowable humidity up to 75%
    Dimensions 20x92x17 mm
    Weight 38 grams